HQR-1/2/3/4 Differential Thermal Analyzer (DTA)
β¬150,000.00
https://www.cn-henven.com/products/differential-thermal-analyzer-dta/ β
#dta #analysis
The differential thermal analyzer investigates the correlation between sample temperature and its diverse physical and chemical properties. Equipped with microcomputer capabilities, the DTA series differential calorimeter enables qualitative analysis of substances, encompassing identification, composition, thermal parameter determination, and purity assessment. It aids in discerning whether thermal effects arise from physical or chemical processes and delves into phenomena such as phase transition, decomposition, combination, resolution, solidification, crystallization, evaporation, and sublimation in substances.
Instrument Feature of DTA Analysis System (DTA)
1.Furnace controlled automatic lifting, positioning accuracy, improved measurement repeatability.
2.Atmosphere control system use the flow controller (MFC), steady flow of gas can automatically switches in the process of experiment, high precision, good repeatability, response speed. (can be customized resistance to all kinds of corrosive gas atmosphere control system).
3.All measurement process automatically, automatic drawing. Special data processing (DTA peak area and heat enthalpy calculation, kinetic parameters calculation, data comparison, many algorithms calculate the activation energy and glass transition temperature and comparison method to measure specific heat, etc.).
4.System to collect samples in the process, can be arbitrary moment screenshot, according to the size of the output signal automatic transformation range.
5.Users can use indium, tin, lead and standard sample on the accuracy of the instrument of temperature, energy correction.
6.The instrument is equipped with a rapid cooling system (the furnace temperature drops from 1550 β to room temperature for β€ 15 minutes).
7.The user the calculation formula and calculation method, our factory can provide the corresponding software development products.
8.Independent research and development of the constant temperature controller; Constant temperature gas chromatography and mass spectrometry connected head; Constant temperature; Can fully guarantee the tar and various kinds of secondary reaction gas detection.
Instrument Parameter of Differential Thermal Analyzer Instrument (DTA)
The abscissa axis can select temperature or time as the scale
LCD real-time display of furnace temperature, sample temperature, gas circuit status, etc
The glass transition temperature,specific heat measurements
Cooling curve function
Crystallization kinetics
72 hours of constant temperature at any temperature point
Temperature data
Temperature Measuring range HQR-1:RTο½1150β
HQR-2:RTο½1250β
HQR-3:RTο½1450β
HQR-4:RTο½1550β
The temperature accuracy Β±0.1β
Heating rate 0.1β/min ~ 100β/min
Vacuum degree(the instrument itself has vacuum sealing measures) Up to 2.5 after optional vacuum unit Γ 10-2Β Pa
Atmosphere control system Mass flow controller (atmosphere control system with various corrosive gases can be customized)
Constant temperature controller, constant temperature gas chromatography, mass spectrometry connector; Constant temperature belt (optional) Constant temperature range: room temperature~400 β
DTA data
Measuring range Β±10ΞΌv~Β±2000ΞΌv
DTA resolution 0.01ΞΌ v
Ceramic 0.06ml Β 0.12ml Platinum (Pt) Β 0.06ml
If you want to know more details of thermogravimetric differential thermal analysis, please visit our website.
#dta #analysis
The differential thermal analyzer investigates the correlation between sample temperature and its diverse physical and chemical properties. Equipped with microcomputer capabilities, the DTA series differential calorimeter enables qualitative analysis of substances, encompassing identification, composition, thermal parameter determination, and purity assessment. It aids in discerning whether thermal effects arise from physical or chemical processes and delves into phenomena such as phase transition, decomposition, combination, resolution, solidification, crystallization, evaporation, and sublimation in substances.
Instrument Feature of DTA Analysis System (DTA)
1.Furnace controlled automatic lifting, positioning accuracy, improved measurement repeatability.
2.Atmosphere control system use the flow controller (MFC), steady flow of gas can automatically switches in the process of experiment, high precision, good repeatability, response speed. (can be customized resistance to all kinds of corrosive gas atmosphere control system).
3.All measurement process automatically, automatic drawing. Special data processing (DTA peak area and heat enthalpy calculation, kinetic parameters calculation, data comparison, many algorithms calculate the activation energy and glass transition temperature and comparison method to measure specific heat, etc.).
4.System to collect samples in the process, can be arbitrary moment screenshot, according to the size of the output signal automatic transformation range.
5.Users can use indium, tin, lead and standard sample on the accuracy of the instrument of temperature, energy correction.
6.The instrument is equipped with a rapid cooling system (the furnace temperature drops from 1550 β to room temperature for β€ 15 minutes).
7.The user the calculation formula and calculation method, our factory can provide the corresponding software development products.
8.Independent research and development of the constant temperature controller; Constant temperature gas chromatography and mass spectrometry connected head; Constant temperature; Can fully guarantee the tar and various kinds of secondary reaction gas detection.
Instrument Parameter of Differential Thermal Analyzer Instrument (DTA)
The abscissa axis can select temperature or time as the scale
LCD real-time display of furnace temperature, sample temperature, gas circuit status, etc
The glass transition temperature,specific heat measurements
Cooling curve function
Crystallization kinetics
72 hours of constant temperature at any temperature point
Temperature data
Temperature Measuring range HQR-1:RTο½1150β
HQR-2:RTο½1250β
HQR-3:RTο½1450β
HQR-4:RTο½1550β
The temperature accuracy Β±0.1β
Heating rate 0.1β/min ~ 100β/min
Vacuum degree(the instrument itself has vacuum sealing measures) Up to 2.5 after optional vacuum unit Γ 10-2Β Pa
Atmosphere control system Mass flow controller (atmosphere control system with various corrosive gases can be customized)
Constant temperature controller, constant temperature gas chromatography, mass spectrometry connector; Constant temperature belt (optional) Constant temperature range: room temperature~400 β
DTA data
Measuring range Β±10ΞΌv~Β±2000ΞΌv
DTA resolution 0.01ΞΌ v
Ceramic 0.06ml Β 0.12ml Platinum (Pt) Β 0.06ml
If you want to know more details of thermogravimetric differential thermal analysis, please visit our website.
You might also like
Slim Down with Every Sip: The Fitspresso Coffee Loophole
star
star
star
star
star
4.0/5
$0.00
Discount London theatre tickets
star
star
star
star
star
4.0/5
$22.00
Professional Dissertation Writers India | Mythsis
star
star
star
star
star
4.0/5
$0.00
Buy YouTube Views
star
star
star
star
star
4.0/5
$30.00