TSC-01 Stand Alone Controller
Tinko TSC-01 integrated single zone hot runner controller is suitable for small mold. The portable controller is of small size, light weight, complete functions and easy to operate. It is really a very smart and economic choice for your hot runner controller system.

This controller is pre-wired for 3 wires (AC-AC-Ground), single phase 240VAC. The integrated construction can provide good protection for the internal control unit. What's more, this mini controller at a good hot runner controller price can provide strong anti-interference, high temperature control accuracy and strong stability.

Features of TSC-01 Stand Alone Controller
Compact stand alone cabinet design

Small and light, easy to operate

LED display

PID control

Auto/Manual

Dehumidify soft start, protect machine

Internal alarm buzzer

Smart & economical for hot runner system

Specification of TSC-01 Stand Alone Controller
Power Supply 1-phase, 85-265Va, 50-60Hz
Temperature unit Β°C or Β°F
Thermocouple J or K
Output 240Vac, 15Amps per zone
Control Mode Auto, Manual, Standby
Power Control Phase Angle, Zero Crossing
Measurement Range 0~500Β°C(32~932Β°F)
Calibration Accuracy Β± 0.25% Full scale
Setting Range 0~450Β°C(32~842Β°F)
Control Accuracy Β± 0.5Β°C
Working environment -0~55Β°C, 10~80% RH(No condensing)

Functions of TSC-01 Stand Alone Controller
Wiring (can be customized)
hot runner temperature controller market
Ultra-high or ultra-low Temperature

Over voltage of power supply

Thermocouple break, short or inverse

Thermocouple is out of its position

Heater break, short or overload

Output device is damaged

Thermocouple & heater misconnection

Alarms & Protection
High/Low temperature alarm

Thermocouple open, reverse, short alarm

Heater open, short, overload alarm

Fuse blown alarm

Plastic leakage detection

Overload protection, cut off output

Short Circuit protection, cut off output

Triac damage protection, cut off output